PRIMERGYPRIMERGY RX200 S2Serversystem Options GuideJoachim PicholFujitsu Siemens Computers GmbH Paderborn33094 Paderborne-mail: email: manuals@fujit
2 Options Guide Overview of the documentation Preface– The “BIOS Setup” manual (PDF available on the ServerBooks CD supplied)– The “Service Suppl
Options Guide 3Preface Extensions and conversions1.2 Extensions and conversionsSecond processorThe system board can be upgraded with a second pr
4 Options Guide Extensions and conversions PrefaceAdditional controllers in non-hot-plug PCI slotsThe system board offers two PCI-X slots:– PCI-X
Options Guide 5Preface Notational conventions1.3 Notational conventionsThe following notational conventions are used in this manual:Italics indi
Options Guide 72ProcedureV CAUTION!● The actions described in this manual should only be performed by engineers, service personnel or technical
Options Guide 93 Safety InstructionsI The following safety instructions can also be found in the manual entitled “Safety”.This device complies w
10 Options Guide Safety InstructionsInstallation and operationV CAUTION!● If the rack model is integrated in an installation that receives power
Options Guide 11Safety InstructionsV CAUTION!● Be careful to ensure that no objects (e.g. jewelry, paper clips etc.) or liquids get inside the d
This manual is printed on paper treated with chlorine-free bleach.Comments… Suggestions… Corrections…The User Documentation Department would like tokn
12 Options Guide Safety InstructionsBatteriesV CAUTION!● Incorrect replacement of batteries may lead to risk of explosion. The batteries may only
Options Guide 13Safety InstructionsI To protect the CD-ROM/DVD drive and prevent mechanical damage, as well as premature wearing of the CDs, you
14 Options Guide Safety InstructionsV CAUTION!● Always hold components with ESDs at the points marked green (touch points).● Do not touch any exp
Options Guide 154 PreparationV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.4.1 Opening the se
16 Options Guide Opening the server PreparationIn the majority of cases it makes sense to remove the server from the rack.V CAUTION!There is no c
Options Guide 175Main MemoryV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.The eight slots for
18 Options Guide Upgrading / exchanging main memory Main Memory5.2 Upgrading / exchanging main memory Ê Open the server as described in the chapt
Options Guide 196 ProcessorsV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.V CAUTION!Processor
20 Options Guide Installing a second processor ProcessorsRemoving the ventilation ductFigure 6: Removal of the ventilation ductÊ Lift off the ven
Options Guide 21Processors Installing a second processorRemoving the heat sink dummy Figure 7: Removing the heat sink dummyÊ Remove the heat sin
PrefaceProcedureSafety InstructionsPreparationMain MemoryProcessorsAccessible DrivesControllers in Non-Hot-Plug PCI SlotsRemoteView ComponentsCompleti
22 Options Guide Installing a second processor ProcessorsFigure 9: Installing the processor Ê Position the new processor over the socket and fit
Options Guide 23Processors Installing a second processorInstalling the heat sinkFigure 10: Installing the heat sinkÊ Fit the heat sink on the pr
24 Options Guide Exchanging the processor Processors6.2 Exchanging the processor V CAUTION!You may only use processors of the same type on the sy
Options Guide 25Processors Exchanging the processorFigure 12: Removing the old processor Ê Release the socket lever by pressing it sideways and
26 Options Guide Exchanging the processor ProcessorsÊ Apply a small amount of thermal paste to the top of the new processor.Ê Spread the paste th
Options Guide 27Processors Exchanging the heat sink6.3 Exchanging the heat sinkÊ Open the server as described in the chapter “Preparation” on pa
Options Guide 297 Accessible DrivesV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.The PRIMERGY
30 Options Guide Installing the LocalView Module Accessible Drives7.1 Installing the LocalView ModuleThe LocalView module is an optional extra fo
Options Guide 31Accessible Drives Installing the LocalView ModuleÊ Remove the dummy cover with a screwdriver.V CAUTION!Keep the dummy cover for
32 Options Guide Installing a CD-ROM/DVD drive Accessible Drives7.2 Installing a CD-ROM/DVD driveYou can install a CD-ROM/DVD drive in the top ri
Options Guide 33Accessible Drives Installing a CD-ROM/DVD driveInstalling a CD-ROM/DVD driveFigure 17: Mounting the drive in its frameÊ Insert t
34 Options Guide Installing a CD-ROM/DVD drive Accessible DrivesFigure 18: Installing the CD-ROM/DVD driveÊ Plug the data cable (1) and the power
Options Guide 35Accessible Drives Installing a floppy disk drive7.3 Installing a floppy disk driveYou can install a floppy disk drive in the top
36 Options Guide Installing a floppy disk drive Accessible DrivesRemoving/installing a floppy disk driveFigure 20: Mounting the drive in its fram
Options Guide 37Accessible Drives Installing a floppy disk driveFigure 21: Connecting the data cableÊ Remove the capton foil from the data cable
Options Guide 398 Controllers in Non-Hot-Plug PCI Slots V CAUTION!Please observe the safety information in the chapter “Safety Instructions” on
40 Options Guide Installing controllers Controllers in Non-Hot-Plug PCI Slots8.1 Installing controllers Ê Open the server as described in the cha
Options Guide 41Controllers in Non-Hot-Plug PCI Slots Installing controllersFigure 23: Mounting the boardÊ Plug the board into the PCI slot on t
AbbreviationsRelated publicationsIndex
Options Guide 439 RemoteView ComponentsV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.9.1 Inst
44 Options Guide Installing the RemoteView Service Board S2 LP RemoteView ComponentsFigure 24: Installing the RSB S2 LPÊ Remove the slot cover.I
Options Guide 4510 CompletionV CAUTION!Please observe the safety information in the chapter “Safety Instructions” on page 9ff.10.1 Closing the s
46 Options Guide Closing the server CompletionFigure 26: Installing the serverÊ Slide the server into the rack (1).I After you have inserted the
Options Guide 47AbbreviationsACAlternating CurrentANSIAmerican National Standards InstituteASR&RAutomatic Server Reconfiguration and Restart
48 Options Guide AbbreviationsDIMMDual Inline Memory ModuleDIPDual Inline PackageDMADirect Memory AccessDMIDesktop Management InterfaceECCError C
Options Guide 49AbbreviationsGAMGlobal Array ManagerGUIGraphical User InterfaceHDDHard Disk DriveHSCHot-Swap ControllerI²CInter-Integrated Circu
50 Options Guide AbbreviationsLVDLow-Voltage Differential SCSIMMFMulti-Mode FiberMRLManual-Retention LatchNMINon-Maskable InterruptNVRAMNon-Volat
Options Guide 51AbbreviationsRTDSRemote Test and Diagnosis SystemSAF-TESCSI Accessed Fault-Tolerance EnclosuresSBESingle-Bit ErrorSCASingle-Conn
Options Guide 53Related publicationsPRIMERGY manuals are available as PDF file on the ServerBooks CD. The ServerBooks CD is part of the ServerSt
54 Options Guide Related publications[12] PRIMERGY ServerView Suite ServerStart[13] PRIMERGY RX200 S2 Service Supplement[14] System Board D1790
Options Guide 55IndexAaccessible drives 3additional documentation 1Bbatteries 12CCD-ROM/DVD driveinstallation 33upgrade 32controller
56 Options Guide Indexintroduction 4removalcover 16riser card holder 40ventilation duct 20riser card holderinstallation 41removal 40T
Comments on PRIMERGY RX200 S2Serversystem CommentsSuggestionsCorrections✁Submitted byFujitsu Siemens Computers GmbHUser Documentation33094 Paderborn
Comments on PRIMERGY RX200 S2Serversystem CommentsSuggestionsCorrections✁Submitted byFujitsu Siemens Computers GmbHUser Documentation33094 Paderborn
Options Guide Contents1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Overview of the
Options Guide 11 PrefaceThe PRIMERGY RX200 S2 is an Intel-based server for mid-tier applications in server farms. The server is well suited for
Commentaires sur ces manuels