Fujitsu TX200 S6 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Serveurs Fujitsu TX200 S6. Fujitsu TX200 S6 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 126
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Server

Operating Manual - EnglishPRIMERGY TX200 S6Server Operating ManualEdition July 2010

Page 2 - Copyright and Trademarks

Operating Manual TX200 S6Contents8.2.5.1 Installing system fan 1 (and 3) . . . . . . . . . . . . . . . 1128.2.5.2 Installing system f

Page 3 - Before reading this manual

100 Operating Manual TX200 S6CSS components8.1.2.6 Installing the HDD moduleUnlocking the HDD moduleFigure 25: Unlocking the 3.5-inch and 2.5-inch HDD

Page 4

TX200 S6 Operating Manual 101CSS componentsInstalling the HDD moduleFigure 26: Installing the 3.5-inch and 2.5-inch HDD modulesÊ Unlock the HDD module

Page 5 - TX200 S6 Operating Manual

102 Operating Manual TX200 S6CSS components8.1.2.7 Removing the HDD moduleV CAUTION!● Only remove a HDD module during operation if the drive is not cu

Page 6 - Operating Manual TX200 S6

TX200 S6 Operating Manual 103CSS componentsÊ Install the new HDD module, as described in "Installing the HDD module" on page 101.V CAUTION!I

Page 7 - Contents

104 Operating Manual TX200 S6CSS components8.2.1 Opening the server and identifying the defective CSS component8.2.1.1 Opening the serverV CAUTION!The

Page 8

TX200 S6 Operating Manual 105CSS components8.2.1.2 Removing system fan 2 (and 4) Figure 28: System fan 2 and system fan 2&4The standard system fan

Page 9

106 Operating Manual TX200 S6CSS componentsÊ Disconnect the fan cable from the connector FAN2 (if there is a second fan cable, disconnect this from FA

Page 10 - TX200 S6

TX200 S6 Operating Manual 107CSS componentsFigure 31: Example: Removing system fan 1&3Ê Disconnect the fan cable from the connector FAN1 on the sy

Page 11 - 1 Preface

108 Operating Manual TX200 S6CSS components8.2.2 Replacing a memory module8.2.2.1 Removing a defective memory moduleFigure 32: Removing a memory modul

Page 12 - 1.2 Documentation overview

TX200 S6 Operating Manual 109CSS components8.2.3 Replacing the system fanV CAUTION!Since the standard system fans 1 and 2 are not redundant, these sys

Page 13 - TX200 S6 Operating Manual 13

TX200 S6 Operating Manual 111 PrefaceThe PRIMERGY TX200 S6 server is an Intel-based server for mid-size and large companies. The server is suitable fo

Page 14 - 1.3 Features

110 Operating Manual TX200 S6CSS components8.2.4 Replacing an expansion card8.2.4.1 Removing a defective expansion cardFigure 34: Removing a defective

Page 15

TX200 S6 Operating Manual 111CSS components8.2.4.2 Installing a new expansion cardFigure 35: Installing a new expansion cardÊ Carefully press the new

Page 16

112 Operating Manual TX200 S6CSS components8.2.5 Reinstalling the fans and closing the server8.2.5.1 Installing system fan 1 (and 3)Figure 36: Install

Page 17 - TX200 S6 Operating Manual 17

TX200 S6 Operating Manual 113CSS components8.2.5.2 Installing system fan 2 (and 4)Ê Connect the fan cable to the connector FAN2 (if there is a second

Page 18 - I Please note the following:

114 Operating Manual TX200 S6CSS components8.2.5.3 Closing the serverFigure 38: Closing the server (example: floorstand model)Ê Pull the locking lever

Page 19 - TX200 S6 Operating Manual 19

TX200 S6 Operating Manual 1159 Appendix: server specificationThis section explains the specifications for the server. The specifications for this serv

Page 20

116 Operating Manual TX200 S6Appendix: server specificationOnboard or integrated controllersSerial 2 (9-pin) 1 x serial RS-232-C, optional - occupies

Page 21 - TX200 S6 Operating Manual 21

TX200 S6 Operating Manual 117Appendix: server specificationPCI-SlotsDrive baysOperating PanelPCI-Express 2.0 x4 (mech. x8)2 x full height (1x long, 1x

Page 22

118 Operating Manual TX200 S6Appendix: server specificationWeightDimensions (Base unit specific)EnvironmentalService displays (optional):ServerView Lo

Page 23 - TX200 S6 Operating Manual 23

TX200 S6 Operating Manual 119Appendix: server specificationElectrical valuesPower supply configuration 1x standard, 1x hot-plug or 2x redundantMax. o

Page 24

12 Operating Manual TX200 S6Preface1.1 Concept and target groups for this manualThis operating manual describes how to install, set up and operate you

Page 25 - 1.4 Notational conventions

120 Operating Manual TX200 S6Appendix: server specification

Page 26 - 1.5 Technical data

TX200 S6 Operating Manual 121Index3rd party rackinstalling in 57requirements 50Aacclimatization time 45, 97Advanced Video Redirection 21ambient condit

Page 27 - TX200 S6 Operating Manual 27

122 Operating Manual TX200 S6Indexenvironmental protection 43errordrifting display on monitor 87drive “dead” 88drive defective 89incorrect date 88inco

Page 28

TX200 S6 Operating Manual 123IndexLlabels 44LAN activity indicator 75LAN transfer rate, indicator 75laser information 37light emitting diode (LED) 37l

Page 29 - TX200 S6 Operating Manual 29

124 Operating Manual TX200 S6IndexSAS/SATA RAID controller 17configuring 79saving energy 43screenerror message 89flickering 87remains blank 86shows fl

Page 30

TX200 S6 Operating Manual 125Indexservice 23TPM 15transport damage 29, 46transporting the server 41troubleshooting 85Trusted Platform Module 15Uunpack

Page 32

TX200 S6 Operating Manual 13PrefaceI PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of

Page 33

14 Operating Manual TX200 S6Preface1.3 FeaturesCustomer Self Service (CSS)The PRIMERGY Customer Self Service (CSS) concept enables you to identify and

Page 34

TX200 S6 Operating Manual 15PrefaceSystem boardThe features of the system board are described in the technical manual for the system board D2799 for t

Page 35

16 Operating Manual TX200 S6PrefaceHard disk drivesThe server is shipped with one of the following drive cages:– For up to four 3.5-inch SAS/SATA hard

Page 36

TX200 S6 Operating Manual 17PrefaceOnboard SATA controllerA SATA controller is integrated on the system board; up to four SATA hard disk drives can be

Page 37

18 Operating Manual TX200 S6PrefaceFurther information on other SAS/SATA RAID controllers (e.g. for operating external SAS/SATA hard disk drives or ta

Page 38 - Figure 1: ESD label

TX200 S6 Operating Manual 19PrefacePower supplyIn its basic configuration the server has a permanently installed power supply unit or a hot-plug power

Page 39 - 3.2 ENERGY STAR

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our

Page 40 - 3.3 CE conformity

20 Operating Manual TX200 S6PrefaceHigh level of availability and data securityWhen memory data is accessed, 1-bit errors are identified in the main m

Page 41

TX200 S6 Operating Manual 21PrefaceiRMC S2 with integrated management LAN connectorI The features of the iRMC S2 Advanced Video Redirection and Remote

Page 42

22 Operating Manual TX200 S6PrefaceServer managementServer management is implemented using the ServerView Operations Manager supplied and the PDA (Pre

Page 43 - 3.7 Environmental protection

TX200 S6 Operating Manual 23PrefaceServerView Installation ManagerYou can configure the PRIMERGY server quickly and precisely with the ServerView Inst

Page 44

24 Operating Manual TX200 S6PrefaceServerView Remote ManagementServerView Remote Management is the remote management solution from Fujitsu for PRIMERG

Page 45

TX200 S6 Operating Manual 25Preface1.4 Notational conventionsThe following notational conventions are used in this manual:Text in italics indicates co

Page 46

26 Operating Manual TX200 S6Preface1.5 Technical dataElectrical dataCompliance with regulations and standardsRated voltage range 100 V - 240 VFrequenc

Page 47

TX200 S6 Operating Manual 27PrefaceMechanical specificationsWeightmax. 36.8 kg (depending on configuration).Ventilation clearanceAt least 200 mm on th

Page 48

28 Operating Manual TX200 S6PrefaceNoise level with standard fan and standard power supply unitsNoise level with redundant system fans and redundant p

Page 49

TX200 S6 Operating Manual 292 Installation steps, overviewThis chapter contains an overview of the steps you need to carry out to install your server.

Page 50

TX200 S6 Operating ManualBefore reading this manualFor your safetyThis manual contains important information for safely and correctly using this produ

Page 51 - Hardware installation

30 Operating Manual TX200 S6Installation steps, overviewÊ Configure the server and install the desired operating system and applications. The followin

Page 52 - 19-inch standard rack

TX200 S6 Operating Manual 313 Important informationIn this chapter you will find essential information regarding safety when working on your server.3.

Page 53 - TX200 S6 Operating Manual 53

32 Operating Manual TX200 S6Important informationBefore starting upV CAUTION!● During installation and before operating the device, observe the instru

Page 54 - I For the Japanese market:

TX200 S6 Operating Manual 33Important informationV CAUTION!● Ensure that the power sockets on the device and the properly grounded power outlets are f

Page 55

34 Operating Manual TX200 S6Important informationV CAUTION!● Proper operation of the system (in accordance with IEC 60950-1 resp. EN 60950-1) is only

Page 56 - Inserting the server

TX200 S6 Operating Manual 35Important informationV CAUTION!● Install the screw removed during installation/detaching Internal Options in former device

Page 57

36 Operating Manual TX200 S6Important informationWorking with CDs/DVDs/BDs and optical drivesWhen working with devices with optical drives, these inst

Page 58

TX200 S6 Operating Manual 37Important information● Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a

Page 59 - TX200 S6 Operating Manual 59

38 Operating Manual TX200 S6Important informationModules with Electrostatic-Sensitive DevicesModules with electrostatic-sensitive devices are identifi

Page 60

TX200 S6 Operating Manual 39Important informationOther important information:● During cleaning, observe the instructions in section "Cleaning the

Page 61 - TX200 S6 Operating Manual 61

Operating Manual TX200 S6These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic contr

Page 62 - 4.5.1 Using cable ties

40 Operating Manual TX200 S6Important information3.3 CE conformity3.4 FCC Class A Compliance StatementIf there is an FCC statement on the device, it a

Page 63

TX200 S6 Operating Manual 41Important informationThe use of shielded I/O cables is required when connecting this equipment to any and all optional per

Page 64 - 64 Operating Manual TX200 S6

42 Operating Manual TX200 S6Important information3.6 Notes on installing the server in the rackV CAUTION!● For safety reasons, at least two people are

Page 65

TX200 S6 Operating Manual 43Important information3.7 Environmental protectionEnvironmentally-friendly product design and developmentThis product has b

Page 66 - Starting up and operation

44 Operating Manual TX200 S6Important informationAll batteries containing pollutants are marked with a symbol (a crossed-out garbage can). They are al

Page 67 - Ê Unlock the server (1)

TX200 S6 Operating Manual 454 Hardware installationV CAUTION!● Follow the safety instructions in the chapter "Important information" on page

Page 68 - 5.2.1 Front of server

46 Operating Manual TX200 S6Hardware installation4.1 Unpacking the serverV CAUTION!Follow the safety instructions in chapter "Important informati

Page 69

TX200 S6 Operating Manual 47Hardware installation4.2 Setting up the floorstand modelI If you are not installing a PRIMERGY TX200 S6 floorstand model,

Page 70

48 Operating Manual TX200 S6Hardware installation4.2.1 Mounting the anti-tilt bracketI The anti-tilt bracket is only necessary for the redundant confi

Page 71 - TX200 S6 Operating Manual 71

TX200 S6 Operating Manual 49Hardware installation4.3 Installing/removing the rack modelV CAUTION!● Please observe the safety information and notes on

Page 72

TX200 S6 Operating ManualOnly for the Japanese market:I Although described in this manual, some sections do not apply to the Japanese market. These op

Page 73 - 5.2.2 Rear of server

50 Operating Manual TX200 S6Hardware installationI For PRIMECENTER Racks and DataCenter Racks:The mounting of the rails in the different racks is desc

Page 74

TX200 S6 Operating Manual 51Hardware installationFigure 3: Mechanical requirements735 - 770 mm100 mm+/- 1,6mm

Page 75 - TX200 S6 Operating Manual 75

52 Operating Manual TX200 S6Hardware installation– You must ensure that the safety mechanisms on the server, e.g. stoppers or retaining systems, are f

Page 76

TX200 S6 Operating Manual 53Hardware installationFitting the support bracketWhen mounting the left support system in the corresponding rack, the suppl

Page 77

54 Operating Manual TX200 S6Hardware installationInstalling the support systemsFigure 5: Fit the left support system in the PRIMECENTER/DataCenter rac

Page 78

TX200 S6 Operating Manual 55Hardware installationI The support system no longer has to be fixed to the front support upright because the easy lock eng

Page 79 - 5.4 Configuring the server

56 Operating Manual TX200 S6Hardware installationInserting the serverFigure 7: Inserting the server (a)Figure 8: Inserting the server (b)1200345566

Page 80

TX200 S6 Operating Manual 57Hardware installationV CAUTION!Ensure that the safety lock has been inserted before the server is inserted (see figure 5 o

Page 81 - TX200 S6 Operating Manual 81

58 Operating Manual TX200 S6Hardware installationI Under certain circumstances, you will not be able to use some of the parts from the rack installati

Page 82

TX200 S6 Operating Manual 59Hardware installation4.4 Connecting devices to the serverThe connectors for external devices are on the front and rear of

Page 84 - Property and data protection

60 Operating Manual TX200 S6Hardware installationConnecting the monitorÊ Connect the monitor to the video connector of the server (see figure 9 on pag

Page 85

TX200 S6 Operating Manual 61Hardware installationFigure 10: Connecting the server to the mainsÊ Connect the power cord to the server power supply unit

Page 86 - 7.3 Screen remains blank

62 Operating Manual TX200 S6Hardware installation4.5.1 Using cable tiesAs an option, you can secure the power cable using a cable tie to ensure that t

Page 87

TX200 S6 Operating Manual 63Hardware installation4.6 Notes on connecting/disconnecting cablesV CAUTION!Always read the documentation supplied with the

Page 88 - 7.6 Incorrect date and time

64 Operating Manual TX200 S6Hardware installation

Page 89 - 7.9 Error message on screen

TX200 S6 Operating Manual 655 Starting up and operationV CAUTION!Follow the safety instructions in chapter "Important information" on page 3

Page 90

66 Operating Manual TX200 S6Starting up and operationFigure 13: Removing the drive cover from the hard disk drive coverÊ Carefully pull out on the gre

Page 91

TX200 S6 Operating Manual 67Starting up and operation5.1.2 Access to the HDD modulesFigure 14: Removing the hard disk coverÊ Unlock the server (1).Ê R

Page 92

68 Operating Manual TX200 S6Starting up and operation5.2 Control elements and indicators5.2.1 Front of serverFigure 15: Front of server (example: rack

Page 93

TX200 S6 Operating Manual 69Starting up and operation5.2.1.1 ID cardYou can pull out the ID card as far as it will go and push it back in again.The ID

Page 94

TX200 S6 Operating ManualContents1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.1 Concept and

Page 95 - /0 1234 5

70 Operating Manual TX200 S6Starting up and operation5.2.1.3 LEDs on the control panelPower indicator (two-color)Glows green when the server is switch

Page 96 - /0 1 2345

TX200 S6 Operating Manual 71Starting up and operation5.2.1.4 Indicators on the drivesDVD drive activity indicatorLights up green when the storage medi

Page 97

72 Operating Manual TX200 S6Starting up and operationHard disk drive indicatorsFigure 16: Indicators on the 3.5 inch and 2.5 inch HDD modules1 HDD BUS

Page 98

TX200 S6 Operating Manual 73Starting up and operation5.2.2 Rear of server5.2.2.1 Indicators on the connector panelCSS, Global Error and ID indicatorsF

Page 99

74 Operating Manual TX200 S6Starting up and operationCSS CSS indicator (yellow)– Lights up yellow if a prefailure event was detected for a CSS compone

Page 100

TX200 S6 Operating Manual 75Starting up and operationLAN indicatorsFigure 18: Indicators on the connector panel: LAN indicatorsI Depending on the sett

Page 101 - TX200 S6 Operating Manual 101

76 Operating Manual TX200 S6Starting up and operation5.2.2.2 Indicators on the hot-plug power supply unitFigure 19: Indicators on the hot-plug power s

Page 102 - V CAUTION!

TX200 S6 Operating Manual 77Starting up and operation5.3 Switching the server on and offV CAUTION!It nothing appears on the screen but flickering stri

Page 103

78 Operating Manual TX200 S6Starting up and operationI If the operating system does not switch the server off automatically, press the On/Off button f

Page 104

TX200 S6 Operating Manual 79Starting up and operation5.4 Configuring the serverThis section contains information about configuring the server and inst

Page 105 - TX200 S6 Operating Manual 105

Operating Manual TX200 S6Contents4.4 Connecting devices to the server . . . . . . . . . . . . . . . 594.5 Connecting the server to the

Page 106

80 Operating Manual TX200 S6Starting up and operationA separate utility is available to the controller for MegaRAID configuration. For further informa

Page 107 - TX200 S6 Operating Manual 107

TX200 S6 Operating Manual 81Starting up and operationIf you are using the ServerView Installation Manager, you can skip the following section on how t

Page 108

82 Operating Manual TX200 S6Starting up and operation5.5 Cleaning the serverV CAUTION!Switch the server off and disconnect the power plugs from the pr

Page 109

TX200 S6 Operating Manual 836 Property and data protectionThe floorstand model is protected against unauthorized opening by a lock. Apart from this, t

Page 110

84 Operating Manual TX200 S6Property and data protection

Page 111 - TX200 S6 Operating Manual 111

TX200 S6 Operating Manual 857 Troubleshooting and tipsV CAUTION!Follow the safety instructions in the "Safety notes and other important informati

Page 112

86 Operating Manual TX200 S6Troubleshooting and tips7.2 Server switches itself offServer Management has detected an errorÊ Check the error list of Sys

Page 113 - TX200 S6 Operating Manual 113

TX200 S6 Operating Manual 87Troubleshooting and tips7.4 Flickering stripes on monitor screenV CAUTION!Switch off the server immediately. Risk of damag

Page 114

88 Operating Manual TX200 S6Troubleshooting and tips7.6 Incorrect date and timeÊ Set the date and time in the operating system or in the BIOS Setup un

Page 115 - TX200 S6 Operating Manual 115

TX200 S6 Operating Manual 89Troubleshooting and tips7.8 Added drive reported as defectiveRAID controller is not configured for this driveThe drive was

Page 116

TX200 S6 Operating ManualContents7.3 Screen remains blank . . . . . . . . . . . . . . . . . . . . . 867.4 Flickering stripes o

Page 118

TX200 S6 Operating Manual 918 CSS componentsThis chapter describes how to handle CSS components and how to identify defective CSS components and repla

Page 119 - TX200 S6 Operating Manual 119

92 Operating Manual TX200 S6CSS components8.1 Hot-plug componentsThis section describes how to handle hot-plug components and how to modify your serve

Page 120 - 120 Operating Manual TX200 S6

TX200 S6 Operating Manual 93CSS componentsÊ Remove the power cable from the installed power supply unit.Ê Push the green catch in the direction of the

Page 121 - TX200 S6 Operating Manual 121

94 Operating Manual TX200 S6CSS components● Depending on the OS, you can configure the write cache settings for the hard disk drives. However, disable

Page 122

TX200 S6 Operating Manual 95CSS components8.1.2.1 3.5-inch HDD module and dummy moduleFigure 21: 3.5-inch HDD module and dummy module1 Dummy module2 T

Page 123 - TX200 S6 Operating Manual 123

96 Operating Manual TX200 S6CSS components8.1.2.2 2.5-inch HDD module and dummy moduleFigure 22: 2.5-inch HDD module and dummy module1 Dummy module2 T

Page 124

TX200 S6 Operating Manual 97CSS components8.1.2.3 Handling hard disk drives and HDD modulesHard disk drives incorporated in the HDD modules are highly

Page 125 - TX200 S6 Operating Manual 125

98 Operating Manual TX200 S6CSS components8.1.2.4 Floorstand: removing the hard disk coverFor a floorstand server you make the HDD modules accessible

Page 126

TX200 S6 Operating Manual 99CSS components8.1.2.5 Removing/installing the dummy moduleFree slots are provided with dummy modules. Remove the dummy mod

Commentaires sur ces manuels

Pas de commentaire