Appendix B FRU List B-7
For the replacement procedure, see Chapter 12.
B.5 Fan Unit
The fan units generate an airflow between the inside and outside of the server. If an
error occurs in one fan unit, the XSCF detects the error and the normally operating
fan unit starts rotating at a higher speed to cool the server. The M3000 server uses
the fan units (FAN_A) as its main cooling system.
TABLE B-8 shows the fan unit
specifications.
For the replacement procedure, see Chapter 13.
Frequency
50 Hz/60 Hz
Maximum
power
consumption
470 W 460 W 505 W 500 W
Apparent
power
480 VA 517 VA 515 VA 562 VA
Heat
dissipation
1,603.7
BTU/hr
(1692 KJ/hr)
1,569.6
BTU/hr
(1656 KJ/hr)
1,723.1
BTU/hr
(1818 KJ/hr)
1,707.9
BTU/hr
(1800 KJ/hr)
Power factor
0.98 0.89 0.98 0.89
* In a redundant configuration, the rated current per cable is half the value shown in TABLE B-7.
This value applies to the full configuration.
TABLE B-8
Fan Unit Specifications
Item Description
Number of fan units 2
Redundancy 2 units (1 + 1 redundant configuration)
Location Front of the server
Active replacement Yes
Hot replacement Yes
Cold replacement Yes
TABLE B-7 Electrical Specifications (Continued)
Item Specifications