Appendix D UPS Controller D-3
D.3 Configuration of Signal Lines
This section provides the signal definitions.
FIGURE D-2 shows the configuration of signal lines when the UPS is connected.
FIGURE D-2 Connection Between the Server and UPS
TABLE D-1 Signal Line Definitions
Signal Name Definitions Pin Number Remarks
*BPS/*UALM Indicates a UPS error. 6 Normal state: Off
Abnormal state: On
*BTL Indicates that the battery level of the UPS has
decreased and warns that battery power will be
unavailable after a certain period of time has
elapsed.
7 Normal state: Off
Abnormal warning:
On
(Note 1)
*BTL
*BPS/*UALM
*ACOFF
SG
UPS cableUPS Server
7
6
9
5