32 SPARC Enterprise T5440 Server Administration Guide July 2009
2. At the ILOM -> prompt, type:
3. At the ok prompt, type:
4. To cause the parameter changes to take effect, type:
The systems permanently stores the parameter changes and boots automatically
when the OpenBoot configuration variable auto-boot? is set to true (its default
value).
Related Information
“Display the ok Prompt” on page 4
“Disable Automatic System Recovery” on page 32
“Automatic System Recovery” on page 31
Disable Automatic System Recovery
1. Log in to ILOM.
See “Log In to ILOM” on page 28
2. Display the ok prompt.
See “Display the ok Prompt” on page 4.
3. At the ok prompt, type:
-> set /HOST/diag mode=normal
-> set /HOST/diag level=max
-> set /HOST/diag trigger=power-on-reset error-reset
ok setenv auto-boot? true
ok setenv auto-boot-on-error? true
ok reset-all
ok setenv auto-boot-on-error? false