30 SPARC Enterprise T5120 and T5220 Servers Service Manual July 2009
Example of show faulty Output When No Fault is
Present
Example of show faulty Output for Environmental
Faults
Example of show faulty Output for Faults Detected by
POST
Example of show faulty Output for Faults Detected by
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
-----------------------------------------------------------------------------
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/FANBD0/FM0
/SP/faultmgmt/0 | timestamp | Dec 14 23:01:32
/SP/faultmgmt/0/ | timestamp | Dec 14 23:01:32 faults/0
/SP/faultmgmt/0/ | sp_detected_fault | TACH at /SYS/FANBD0/FM0/F0 has
faults/0 | | exceeded low non-recoverable
| | threshold.
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BR1/CH0/D0
/SP/faultmgmt/0 | timestamp | Dec 14 23:01:32
/SP/faultmgmt/0/ | timestamp | Dec 14 23:01:32 faults/0
faults/0 | |
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/BR1/CH0/D0
faults/0 | | Forced fail(POST)