iRMC S2/S3 161
BIOS - Backing up/restore BIOS settings, flashing BIOS
2. Subsequently, flash data is transferred to memory. The status display will
indicate when the transfer has successfully completed.
3. Before the actual flashing process is started, the flash/update image is
checked.
Figure 79: Updating BIOS - checking update/flash image
4. Once the update/flash image is successfully verified, the actual flashing
process is started. The status indication shows the percentage completion
of the flash process.
5. After the BIOS update has successfully completed, the server is powered
off. The following entry is written to the system event log (SEL):
BIOS TFTP or HTTP/HTTPS flash OK
BIOS Information
This group provides information on the current BIOS version on the managed
server.