52 iRMC S2/S3
Configuring text console redirection via LAN
Flow Control
The setting depends on the terminal type used. The settings must be
the same on both terminal and managed server.
Continue C.R. after POST:
This setting affects the behavior of console redirection while the
operating system is running (after the POST phase has completed) -
see section "Using console redirection while the operating system is
running" on page 55:
Off
Console redirection is terminated after the BIOS POST phase.
On
Console redirection continues to be available after the BIOS
POST phase.
Exiting the BIOS / TrustedCore setup utility
Ê Save your settings and exit the BIOS/TrustedCore setup utility.
Ê Continue with section "Testing the LAN interface" on page 47.