iRMC S2/S3 51
Configuring text console redirection via LAN
Mode
This setting affects the behavior of console redirection while the
operating system is running (after the POST phase has completed) -
see section "Using console redirection while the operating system is
running" on page 55:
Standard
Console redirection is terminated after the BIOS POST phase.
Enhanced
Console redirection continues to be available after the BIOS
POST phase.
Ê Make the following settings in the TrustedCore setup utility:
Figure 12: Console Redirection menu (as it appears in the TrustedCore setup utility)
Com Port Address
Set the value to On-board COM A.
Baud Rate
Specify the baud rate.
Console Type
Leave this setting unchanged. (The setting depends on the terminal
type used.)