iRMC S2/S3 205
Power Consumption
Warning Threshold
Threshold as a percentage of the maximum power consumption
specified under Power Limit. When the threshold is reached, the action
defined under Action Reaching Power Limit is performed.
Power Limit Grace Period
Period (in minutes) for which the system waits after the threshold has
been reached until the action is performed.
Action Reaching Power Limit
Action to be performed after the threshold has been reached and the
grace period has expired.
Continue
No action is performed.
Graceful Power Off (Shutdown)
Shut down the system "gracefully" and power it down.
I This option is only supported if ServerView agents are
installed and signed onto the iRMC S2/S3 as “Connected”.
Immediate Power Off
The server is immediately powered down irrespective of the status
of the operating system.
Enable Dynamic Power Control
The power limit is controlled dynamically. If this option is enabled, the
iRMC S2/S3 controls the power consumption of the server system by
reducing the CPU’s power consumption as soon as the Warning Threshold
is reached.