Fujitsu INTEGRATED REMOTE MANAGEMENT CONTROLLER IRMC S2/S3 Manuel d'utilisateur Page 389

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 426
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 388
iRMC S2/S3 389
IPMI OEM Commands supported by the iRMC S2/S3
01 16 - Get Power Off Source
This command returns the reason for the most recent Power Off. The possible
reasons are listed below.
Request Data - B8 NetFnlLUN: OEM/Group
- 01 Cmd : Command Group Communication
1:3 80 28 00 IANA-Enterprise-Number FTS, LS byte first
4 16 Command Specifier
Response Data - BC
- 01
1 Completion Code
2:4 80 28 00 IANA-Enterprise-Number FTS, LS byte first
3 01 Data Length
4 Power off Source: Cause of last power off
Power off
Source
Description
0x00 Software (SWOFF, power off by command)
0x01 Power switch (on the front panel or keyboard)
0x02 AC power fail
0x03 Clock or timer (hardware RTC or software timer)
0x04 Fan failure
0x05 Critical temperature
0x08 Final power-off after repeated watchdog timeouts
0x0C Final power-off after repeated CPU errors
0x1D Powered off by remote control via remote manager